Before performing machine maintenance or cleaning, the upper punch should be aligned with the lower dies and the machine should be lowered and turned off until the work is completed. If startup or other operations are required, the mode should be selected as manual and safety should be ensured. The maintenance content is as follows:
1. Hydraulic oil circuit
1) Check the oil level in the fuel tank every week, and also check it after hydraulic system maintenance. If the oil level is below the oil window, add hydraulic oil;
2) The hydraulic oil used in this machine is ISO HM46 or MOBIL DTE25;
3) The new machine should have its oil changed after 2000 hours of operation, and every 4000-6000 hours of operation thereafter. After each oil change, the oil tank should be cleaned;
4) The syste...